Ω

Resistance Range

Verified to STM7.1, STM97.1, ASTM F150, and STM97.2 for permanent conductivity.

%

Uptime Installation

Adhesive-free and low-VOC systems allow installation in live environments with no operational interruption.

%

Independent of Humidity

Stable performance in any humidity for tightly controlled telecom and network spaces.

%

Lifetime Conductivity Warranty

Conductivity is built into the material, and never dependent on wax or topical treatments.

Problem 1: Static Interference & Signal Integrity

ESD events in telecom and broadcast environments can cause packet loss, switch resets, RF noise, audio/video distortion, or premature equipment failure—especially in low-humidity IDF/MDF spaces and high-density NOCs.

Solution

StaticWorx systems provide permanent, humidity-independent conductivity, verified to ANSI/ESD standards(S20.20, STM97.1/97.2, F150) and IEC 61340. Flooring supports predictable grounding behavior around racks, switches, patch panels, coax/satellite transmission gear, and sensitive broadcast electronics, aligning with grounding and bonding expectations outlined in ATIS 0600321, IBM data center guidelines, and Motorola R56.

Problem 2: Installation in Live Switching Facilities

Telecom, broadcast, and emergency-communications centers must remain fully operational; shutdowns can interrupt service delivery, transmission continuity, or 24/7 monitoring.

Solution

StaticWorx offers adhesive-free and low-odor installation systems, including GroundLock Extreme interlocking tiles, RapidInstall dry adhesive, and StatBond® PSA allowing phased installation with no shutdowns, no VOC-related alarms, and no impact on airflow, pressurization, or equipment cooling. These methods are compatible with the operational requirements of ATIS 0600321, Motorola R56, and IBM telecom room guidelines.

Problem 3: Raised-Access Floors & Ground Continuity

In IDF rooms, data centers, NOCs, and broadcast suites, metal raised-access floors and uneven substrates can introduce grounding discontinuities that compromise ESD control and violate telecom grounding/bonding requirements.

Solution

StaticWorx flooring integrates cleanly with raised-access systems using conductive adhesives, copper grounding straps, and installation practices aligned with Motorola R56, IBM grounding specifications, and ATIS 0600321. For spaces where adhesive is not permitted or shutdowns are impossible, StaticWorx also offers field-applied floating solutions, including GroundLock interlocking tiles and floating ShadowFX carpet tiles that maintain continuous ESD performance without disturbing the access-floor infrastructure.

Problem 4: Long-Term Maintenance & Cost Predictability

Waxed or topically treated ESD floors lose conductivity, require frequent maintenance, and introduce lifecycle costs that telecom and broadcast facilities cannot afford.

Solution

StaticWorx floors require no conductive waxes or coatings, only routine neutral-cleaner maintenance. Because conductivity is intrinsic and permanent, electrical performance remains stable for decades, supporting long-term reliability and predictable lifecycle costs in NOCs, switching centers, IDF/MDF rooms, and broadcast facilities.

What Clients are Saying
quotes

…the floor is awesome! It’s very durable and it’s very convenient that we can lift tiles up to remove debris from underneath, and even replace tiles if they are damaged. So from a functional perspective, this is the best floor for our manufacturing operation.

Tyler Mastromattei, Engineer Advanced Motion Controls
quotes

You would never know it was ESD, WHICH IS AMAZING! Your product rocks and I’m so glad we were able to find an attractive solution that didn’t leave us with some run-of-the-mill ugly disaster in the middle of our workspaces!

Sydnie Young, Associate IIDA FFKR Architects
quotes

Your product is impervious to most/all conditions. It’s impressive. Happy to be working with StaticWorx.

Gary Anderson, President GDA Commercial Flooring, California
Our Process

Ensuring Continuous Operations Through Expert Planning & Verification

1. Site & Operational Assessment

Evaluation of RH controls, raised-floor systems, cable routing, grounding needs, and equipment layout.

2. Specification & Documentation

Full test data, CSI specs, and compliance documentation support procurement and commissioning.

3. Installation Planning

Rapid-install and live-environment options minimize disruption in mission-critical spaces.

4. GroundSafe® Testing

Pre- and post-install testing verifies resistance-to-ground, continuity, and ESD compliance.

5. Maintenance & Lifecycle Support

Cleaning and testing protocols maintain long-term reliability.

6. Training & Education

Training for telecom technicians and facility teams on testing, grounding, and maintenance.

Our Solutions

StaticWorx Products & Services for Telecommunications

Flooring

Conductive/static-dissipative vinyl and rubber, static-dissipative carpet tile, and interlocking ESD systems engineered for raised-access floors, high-load areas, and climate-controlled telecom environments.

Explore

Seating & Accessories

ESD-safe seating, mats, and grounding components that ensure system-wide continuity from operator to floor to ground.

Explore

Installation

Adhesive-free and low-VOC systems protect IAQ and support installation in sensitive equipment rooms.

Explore

Testing & Documentation

GroundSafe® verification provides resistance, body-voltage, and continuity documentation for audits and quality assurance.

Explore
Customized Solutions

Customized Solutions

We provide tailored solutions for any installation with technical support through purchase, installation, testing, and maintenance.